Reliable Supplier 1,D2 Pressure Vessel – Refrigeration Auxillary Vessels – SPL
Reliable Supplier 1,D2 Pressure Vessel – Refrigeration Auxillary Vessels – SPL Detail:
■ SPL Refrigeration Equipment are customized to suit the customer requirement.
■ Designed and manufactured as per the ASME Sec VIII. code.
■ Maintain highest and stringent manufacturing and testing standards.
SPL’s design and manufacturing capability is well equipped to execute complete turnkey projects. Vessels are manufactured with highest quality, corrosion resistant material giving long operational life. We can manufacture in Galvanized Steel, SS 304, SS 316 and SS 316L material. In-house Thermal and Mechanical design of the vessels give complete control on the budget of the project.
Equipment Type |
Equipment Name | Description | Designed Pressure | Vessel Category |
Ammonia Refrigeration Auxiliary Equipment |
Thermosyphon Evaporator _ HZ Series
|
The thermosyphon evaporator is a high efficiency heat exchanger integrated with evaporator and separator, and it is applied to all refrigeration systems that need secondary refrigerant indirect cooling. Refrigerant in the tubes evaporates after absorbing the heat of the secondary refrigerant whose temperature is reduced accordingly. The flash gas generated by throttling is separated with liquid by separator that ensure what enter into the evaporator is all liquid, the separator also separate liquid drop entrained by counter steam, ensure the compressor runs safely. | Shell Side:1.0MPA
Tube Side:1.4MPA Media: Shell Side:Secondary Refrigerant Tube Side:R717
|
II |
Auxiliary Receiver _ FZA Series
|
The Auxiliary Receiver supply liquid refrigerant for oil cooler. It can separate liquid refrigerant from oil cooler gas, and can used as high pressure receiver. | 2.0MPA | II | |
Receiver _ ZA Series
|
The receiver stores the high pressure refrigerant, to accommodate the operating conditions, and meanwhile seal the liquid. | 2.0MPA | II | |
Cleansing-Type Oil Separator _ YF T Series
|
Cleansing-type oil separator is used for separating oil from gas going through ammonia liquid. Also taking advantage of the area’s sudden expansion, it decreases the speed and change the direction to make oil precipitate and separated. | 2.0MPA | II | |
Filler-Type Oil Separator _ YF B Series
|
This device is equipped between the ammonia compressor and condenser. When the ammonia air exhausted from the compressor goes through it, the device can separate the lubricating oil from the ammonia gas due to the reduction of the air flowing speed, the changing of the flowing direction, and adsorption of filler. | 2.0MPA | II | |
Vertical Low Pressure Circulation Receiver _ DXZ1 Series
|
The product is applied for liquid supply system of ammonia pump. It can store the low pressure liquid for pump, and also can separate throttled flash gas and liquid drop from the evaporated gas. | 1.4MPA | II | |
Horizontal Low Pressure Circulation Receiver _ WDXZ Series | The product is applied for liquid supply system of ammonia pump. It can store the low pressure liquid for pump, and also can separate throttled flash gas and liquid drop from the evaporated gas. | 1.4MPA | II | |
Intercooler _ ZL Series
|
Intercooler is used in the double stage of refrigeration system, and equipped between the low-pressure stage and the high-pressure stage. It refrigerate the overheated air exhausted from the low-pressure vat when the air goes through the equipment. Meanwhile it cools the high pressure refrigerant in the coils to get more subcooling. | Outside Coils:1.4MPA, Inside Coils:2.0MPA | II | |
Liquid Separator _ AF Series
|
The ammonia liquid separator is used to separate the liquid from the evaporator to ensure the safe operation of the compressor. Meanwhile, it can separate the flash gas from throttled liquid, and ensure refrigerant which enter into evaporator is all liquid, stabilize the heat transfer effect. | 1.4MPA | II | |
Horizontal Liquid Separator _ WAF Series
|
The horizontal ammonia liquid separator is used to separate the liquid from the evaporator gas to ensure the safe operation of the compressor. Meanwhile, it can separate the flash gas from throttled liquid, and ensure refrigerant which enter into evaporator is all liquid, stabilize the heat transfer effect. | 1.4MPA | II | |
Gas Return Barrel _ WS Series
|
Gas return barrel is used to separate the liquid from the evaporator gas to ensure the safe operation of the compressor. | 1.4MPA | II | |
Oil Receiver _ JY Series
|
The oil receiver collect the separated oil from all the equipment, discharge the oil in low pressure, and also can recycle the refrigerant. | 2.0MPA | II | |
Air Separator _ KF Series
|
The air separator is used to separate the non-condensed gas not liquidized in the condenser or remained in the refrigerating device, to keep the refrigerant in the normal condensing pressure. | 2.0MPA | -
|
|
Urgent Relief _ XA Series
|
The urgent relief is connected with the ammonia storage vessel(such as receiver and evaporator), in urgent condition, open the ammonia valve and water valve, mix the ammonia and water and discharge into sewer. | 2.0MPA | -
|
|
Freon Refrigeration Auxiliary Equipment |
Thermosyphon Evaporator _ HZF Series
|
The urgent relief is connected with the ammonia storage vessel(such as receiver and evaporator), in urgent condition, open the ammonia valve and water valve, mix the ammonia and water and discharge into sewer. | Shell Side:1.0MPA
Tube Side:1.4MPA Media: Shell Side:Secondary Refrigerant Tube Side:Refrigerant |
II |
Auxiliary Receiver _ FZF Series
|
The Auxiliary Receiver supply liquid refrigerant for oil cooler. It can separate liquid refrigerant from oil cooler gas, and can used as high pressure receiver. | 2.1MPA | II | |
Receiver _ ZF Series
|
The receiver stores the high pressure refrigerant, to accommodate the operating conditions, and meanwhile seal the liquid. | 2.1MPA | II | |
Vertical Low Pressure Circulation Receiver _ DXZF Series | The product is used in the fluorine pump refrigeration system. It can store the low pressure liquid for pump, and also can separate throttled flash gas and liquid drop from the evaporated gas. | 1.4MPA | II | |
Horizontal Low Pressure Circulation Receiver _ WDXZF Series | The product is used in the fluorine pump refrigeration system. It can store the low pressure liquid for pump, and also can separate throttled flash gas and liquid drop from the evaporated gas. | 1.4MPA | II | |
Intercooler _ ZLF Series
|
Intercooler is used in the double stage of refrigeration system, and equipped between the low-pressure stage and the high-pressure stage. It refrigerate the overheated air exhausted from the low-pressure vat when the air goes through the equipment. Meanwhile it cools the high pressure refrigerant in the coils to get more subcooling. | Outside Coils:1.4MPA, Inside Coils:2.1MPA | II | |
Gas -Liquid Separator _ QYF Series
|
The gas-liquid separator is used to separate the liquid from the evaporator to ensure the safe operation of the compressor. Meanwhile, it can separate the flash gas from throttled liquid, and ensure refrigerant which enter into evaporator is all liquid, stabilize the heat transfer effect. | 1.4MPA | II | |
Automatic Air Separator_ KFL Series
|
Air separator is used to separate the gas which can’t be liquefied or condensed in the refrigerating system ,and to make the system keep normal condensing pressure. Meanwhile condensed refrigerant will be recycled. | 2.1MPA | II | |
Oil Receiver _ JYF Series
|
The oil receiver collect the separated oil from refrigeration equipment, to make the equipment working normally, and so that push oil back to the compressor. | 1.4MPA | II | |
Liquid Circulated Unit _ YX2B Series
|
Liquid Circulated Unit _ YX2B Series
|
Liquid circulated unit is applied for liquid supply refrigerating system, to provide refrigerant for the system, meanwhile it has function of liquid receiver. It is widely utilized in refrigeration projects on agriculture, commerce, national defense, science research.
Liquid circulated unit consists one horizontal low pressure circulation receiver, two pumps and affiliated parts including filter, check valve, differential pressure controller, level indicator, level controller, auto liquid supply device assembled in same frame, and pipes, valves, auto-control elements, electrical elements are all assembled completely. This unit can realize auto-liquid supply, level indication, high level warning, pump auto-protection, auto or manual operation. |
Product detail pictures:
Related Product Guide:
It truly is our responsibility to fulfill your requirements and successfully provide you. Your fulfillment is our best reward. We're seeking forward in your check out for joint development for Reliable Supplier 1,D2 Pressure Vessel – Refrigeration Auxillary Vessels – SPL, The product will supply to all over the world, such as: Dubai, Estonia, Singapore, We have established long-term, stable and good business relationships with many manufacturers and wholesalers around the world. Currently, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more details.
By Jacqueline from Kuala Lumpur - 2017.02.18 15:54
Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
By June from Switzerland - 2017.01.28 18:53